CE Approved Medical Single Channel Infusion Syringe Pump
Basic Info
Model NO. | DP-602 |
Classification | First Aid Device |
Type | Infusion Syringe Pump |
Certification | CE, ISO13485 |
Group | All Age People |
Power Source | Electric |
Material | Plastic |
Syringe Size | 10, 20, 30, 50/60 Ml |
Accuracy | ±2% (Mechanical Accuracy ≤1%) |
Applicable Syringe | Compatible with Syringe of Any Standard |
Working Temperature | 5-40°c |
Relative Humidity | 20-90% |
Atmospheric Pressure | 860-1060 Hpa |
Transport Package | Carton |
Origin | China |
Production Capacity | 1000 Sets/Month |
Product Description
Application:
ICU, CCU, NICU, emergency, operation room, paediatrics, obstetrics, cardiology, oncology, hematology
Product Features:1) Simple structure in linear type ,easy in installation and maintation.
2) Adopting advanced world famous brand components in pneumatic parts ,electric parts and operation parts.
3) High pressure double crank to control the die opening and closing.
4) Running in a high automatization and intellectualization,no pollution
5) Apply a linker to connect with the air conveyor ,which can directly inline with filling machine .
Techinical Specification:
Model | DP-602 | |||
Syringe Size | 10, 20, 30, 50/60 ml | |||
Applicable Syringe | Compatible with syringe of any standard | |||
VTBI | 0.1-9999 ml<1000 ml in 0.1 ml increments≥1000 ml in 1 ml increments | |||
Flow Rate | Syringe 10 ml: 0.1-400 ml/hSyringe 20 ml: 0.1-600 ml/hSyringe 30 ml: 0.1-900 ml/hSyringe 50/60 ml: 0.1-1300 ml/h<100 ml/h in 0.1 ml/h increments≥100 ml/h in 1 ml/h increments | |||
Bolus Rate | Syringe 10 ml: 400 ml/hSyringe 20 ml: 600 ml/hSyringe 30 ml: 900 ml/hSyringe 50/60 ml: 1300 ml/h | |||
Anti-Bolus | Automatic | |||
Accuracy | ±2% (mechanical accuracy ≤1%) | |||
Infusion Mode | Memory modeFlow rate: ml/min, ml/hTime-basedBody weight: mg/kg/min, mg/kg/h, ug/kg/min, ug/kg/h etc. | |||
KVO Rate | 0.1-1 ml/h (in 0.1 ml/h increments) | |||
Alarms | Occlusion, near empty, end program, low battery, end battery,AC power off, motor malfunction, system malfunction, reminder alarm, pressure sensor error, syringe installation error, syringe drop off | |||
Additional Features | Real-time infused volume, automatic power switching,automatic syringe identification, mute key, purge, bolus, anti-bolus,system memory | |||
Drug Library | Available | |||
Occlusion Sensitivity | High, medium, low | |||
Power Supply, AC | 110/230 V (optional), 50/60 Hz, 20 VA | |||
Battery | 9.6±1.6 V, rechargeable | |||
Battery Life | 7 hours at 5 ml/h | |||
Working Temperature | 5-40ºC | |||
Relative Humidity | 20-90% | |||
Atmospheric Pressure | 860-1060 hpa | |||
Size | 314*167*140 mm | |||
Weight | 2.5 kg | |||
Safety Classification | Class II, type CF |